Table A.77-1 specifies the Modules of the Wide Field Ophthalmic Photography 3D Coordinates Image IOD.
Table A.77-1. Wide Field Ophthalmic Photography 3D Coordinates Image IOD Modules
|
IE |
Module |
Reference |
Usage |
|---|---|---|---|
|
Patient |
Patient |
M |
|
|
Clinical Trial Subject |
U |
||
|
Study |
General Study |
M |
|
|
Patient Study |
U |
||
|
Clinical Trial Study |
U |
||
|
Series |
General Series |
M |
|
|
Ophthalmic Photography Series |
M |
||
|
Clinical Trial Series |
U |
||
|
Frame of Reference |
Frame of Reference |
M |
|
|
Synchronization |
M |
||
|
Equipment |
General Equipment |
M |
|
|
Enhanced General Equipment |
M |
||
|
Image |
General Image |
M |
|
|
Image Pixel |
M |
||
|
Enhanced Contrast/Bolus |
C - Required if contrast was administered; see A.77.4.2 |
||
|
Cine |
C - Required if there is a sequential temporal relationship between all frames |
||
|
Multi-frame |
M |
||
|
Acquisition Context |
U |
||
|
Ophthalmic Photography Image |
M |
||
|
Wide Field Ophthalmic Photography 3D Coordinates |
M |
||
|
Wide Field Ophthalmic Photography Quality Rating |
C - Required if a quality rating value exists for this SOP Instance |
||
|
Ocular Region Imaged |
M |
||
|
Ophthalmic Photography Acquisition Parameters |
M |
||
|
Ophthalmic Photographic Parameters |
M |
||
|
ICC Profile |
C - Required if Photometric Interpretation (0028,0004) is not MONOCHROME2 |
||
|
SOP Common |
M |
||
|
Common Instance Reference |
U |
||
|
Frame Extraction |
C - Required if the SOP Instance was created in response to a Frame-Level retrieve request |