ECG Report Templates 

TID 3700 ECG Report

The ECG Report template is the root structure for the representation of analysis of an ECG waveform, potentially in comparison to a prior ECG waveform analysis. The analyzed waveform may or may not be stored as a DICOM SOP Instance.

Type:

Extensible

Order:

Significant

Root:

Yes

Table TID 3700. ECG Report

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (28010-7, LN, "ECG Report")

1

M

Root node

2

>

HAS CONCEPT MOD

CODE

EV (121058, DCM, "Procedure reported")

1

U

DCID 3670 “ECG Procedure Types”

3

>

HAS CONCEPT MOD

INCLUDE

DTID 1204 “Language of Content Item and Descendants”

1

M

4

>

CONTAINS

INCLUDE

DTID 1002 “Observer Context”

1-n

M

5

>

CONTAINS

CONTAINER

EV (121109, DCM, "Indications for Procedure")

1

U

6

>>

CONTAINS

CODE

EV (121071, DCM, "Finding")

1-n

U

DCID 3671 “Reason for ECG Exam”

7

>>

CONTAINS

TEXT

EV (121071, DCM, "Finding")

1

U

8

>

CONTAINS

INCLUDE

DTID 3802 “Cardiovascular Patient History”

1

U

9

>

CONTAINS

INCLUDE

DTID 3704 “Patient Characteristics for ECG”

1

U

10

>

CONTAINS

INCLUDE

DTID 3702 “Prior ECG Exam”

1

U

11

>

CONTAINS

INCLUDE

DTID 3708 “ECG Waveform Information”

1

M

12

>

CONTAINS

CONTAINER

EV (122144, DCM, "Quantitative Analysis")

1

M

13

>>

CONTAINS

INCLUDE

DTID 3713 “ECG Global Measurements”

1

U

14

>>

CONTAINS

INCLUDE

DTID 3714 “ECG Lead Measurements”

1-n

U

One instantiation per reported lead

15

>

CONTAINS

INCLUDE

DTID 3717 “ECG Qualitative Analysis”

1

U

16

>

CONTAINS

INCLUDE

DTID 3719 “Summary, ECG”

1

U


TID 3701 Clinical Context, ECG (Retired)

This Template has been retired (see PS3.16-2009).

TID 3702 Prior ECG Exam

Type:

Extensible

Order:

Significant

Table TID 3702. Prior ECG Exam

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

CONTAINER

EV (121066, DCM, "Prior Procedure Descriptions")

1

M

2

>

CONTAINS

CODE

EV (122140, DCM, "Comparison with Prior Exam Done")

1

M

DCID 230 “Yes-No”

3

>

CONTAINS

DATETIME

EV (122146, DCM, "Procedure DateTime")

1

U

4

>

CONTAINS

UIDREF

EV (121018, DCM, "Procedure Study Instance UID")

1

U

5

>

CONTAINS

COMPOSITE

EV (122075, DCM, "Prior report for current patient")

1

U

6

>

CONTAINS

WAVEFORM

EV (121112, DCM, "Source of Measurement")

1

U


TID 3704 Patient Characteristics for ECG

Type:

Extensible

Order:

Significant

Table TID 3704. Patient Characteristics for ECG

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (121118, DCM, "Patient Characteristics")

1

M

2

>

CONTAINS

NUM

EV (121033, DCM, "Subject Age")

1

M

UNITS = DCID 7456 “Units of Measure for Age”

3

>

CONTAINS

CODE

EV (121032, DCM, "Subject Sex")

1

M

DCID 7455 “Sex”

4

>

CONTAINS

NUM

EV (8302-2, LN, "Patient Height")

1

U

UNITS = EV (cm, UCUM, "cm")

5

>

CONTAINS

NUM

EV (29463-7, LN, "Patient Weight")

1

U

UNITS = EV (kg, UCUM, "kg")

6

>

CONTAINS

NUM

EV (F-008EC, SRT, "Systolic Blood Pressure")

1

U

UNITS = DCID 3500 “Pressure Units”

7

>

CONTAINS

NUM

EV (F-008ED, SRT, "Diastolic Blood Pressure")

1

U

UNITS = DCID 3500 “Pressure Units”

8

>

CONTAINS

CODE

EV (109054, DCM, "Patient State")

1

U

DCID 3262 “ECG Patient State Values”

9

>

CONTAINS

CODE

EV (R-00728, SRT, "Pacemaker in situ")

1

U

DCID 3672 “Pacemakers”

10

>

CONTAINS

CODE

EV (R-0077C, SRT, "ICD in situ")

1

U

DCID 3692 “ICDs”


TID 3708 ECG Waveform Information

The ECG Waveform Information template provides reference to, and important parameters of, the analyzed waveform.

Type:

Extensible

Order:

Significant

Table TID 3708. ECG Waveform Information

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (121064, DCM, "Current Procedure Descriptions")

1

M

2

>

CONTAINS

WAVEFORM

EV (121112, DCM, "Source of Measurement")

1

U

3

>

CONTAINS

CODE

EV (10:11345, MDC, "Lead System")

1

U

DCID 3263 “Electrode Placement Values”

4

>

CONTAINS

TEXT

EV (122142, DCM, "Acquisition Device Type")

1

U

5

>

CONTAINS

TEXT

EV (121122, DCM, "Equipment Identification")

1

U

6

>

CONTAINS

INCLUDE

DTID 1003 “Person Observer Identifying Attributes”

1

U

Person performing the ECG acquisition

7

>

CONTAINS

TEXT

EV (121121, DCM, "Room Identification")

1

U

8

>

CONTAINS

DATETIME

EV (122146, DCM, "Procedure DateTime")

1

M

9

>

CONTAINS

NUM

DCID 3690 “ECG Control Variables Numeric”

1-n

U

10

>

CONTAINS

TEXT

DCID 3691 “ECG Control Variables Text”

1-n

U

11

>

CONTAINS

INCLUDE

DTID 4019 “CAD Algorithm Identification”

1

U


TID 3713 ECG Global Measurements

The ECG Global Measurements Template provides a structure for measurements calculated across the ECG waveform as a whole (multiple leads).

As an Extensible Template, applications may include any ECG global measurements, such as angles of the electrical vector of various ECG waves. The recommended vocabulary for such concepts is ISO/IEEE 11073-10102.

Type:

Extensible

Order:

Significant

Table TID 3713. ECG Global Measurements

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (122158, DCM, "ECG Global Measurements")

1

M

2

>

HAS OBS CONTEXT

INCLUDE

DTID 3715 “ECG Measurement Source”

1

U

3

>

CONTAINS

NUM

DT (2:16020, MDC, "Atrial Heart Rate")

1

U

UNITS = EV ({H.B.}/min, UCUM, "BPM")

4

>

CONTAINS

NUM

DT (2:16016, MDC, "Ventricular Heart Rate")

1

M

UNITS = EV ({H.B.}/min, UCUM, "BPM")

5

>

CONTAINS

NUM

DT (2:16160, MDC, "QT interval global")

1

M

UNITS = EV (ms, UCUM, "ms")

6

>

CONTAINS

NUM

DT (2:15876, MDC, "QTc interval global")

1

U

UNITS = EV (ms, UCUM, "ms")

7

>>

HAS PROPERTIES

CODE

DT (111001, DCM, "Algorithm Name")

1

U

DCID 3678 “Qt Correction Algorithms”

8

>

CONTAINS

NUM

DT (2:15872, MDC, "PR interval global")

1

M

UNITS = EV (ms, UCUM, "ms")

9

>

CONTAINS

NUM

DT (2:16156, MDC, "QRS duration global")

1

M

UNITS = EV (ms, UCUM, "ms")

10

>

CONTAINS

NUM

DT (2:16168, MDC, "RR interval global")

1

M

UNITS = EV (ms, UCUM, "ms")

11

>

CONTAINS

NUM

DCID 3689 “ECG Global Waveform Durations”

1-n

U

UNITS = EV (ms, UCUM, "ms")

12

>

CONTAINS

NUM

DCID 3229 “ECG Axis Measurements”

1-n

U

UNITS = EV (deg, UCUM, "deg")

13

>

CONTAINS

NUM

DT (2:16032, MDC, "Count of all beats")

1

U

UNITS = EV ({beats}, UCUM, "beats")

14

>

CONTAINS

NUM

DT (122707, DCM, "Number of Ectopic Beats")

1

U

UNITS = EV ({beats}, UCUM, "beats")

15

>>

HAS PROPERTIES

CODE

EV (G-C504, SRT, "Associated Morphology")

1-n

U

BCID 3234 “Ectopic Beat Morphology”


TID 3714 ECG Lead Measurements

The ECG Lead Measurements Template provides a structure for measurements calculated on individual ECG leads.

As an Extensible Template, applications may include any ECG per lead measurements, such as integrals over time of various ECG wave voltages. The recommended vocabulary for such concepts is ISO/IEEE 11073-10102.

Type:

Extensible

Order:

Significant

Table TID 3714. ECG Lead Measurements

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (122159, DCM, "ECG Lead Measurements")

1

M

2

>

HAS CONCEPT MOD

CODE

EV (122148, DCM, "Lead ID")

1

M

BCID 3001 “ECG Leads”

3

>

HAS OBS CONTEXT

INCLUDE

DTID 3715 “ECG Measurement Source”

1

U

4

>

CONTAINS

NUM

DCID 3687 “Electrophysiology Waveform Durations”

1-n

U

UNITS = EV (ms, UCUM, "ms")

5

>

CONTAINS

NUM

DCID 3688 “Electrophysiology Waveform Voltages”

1-n

U

UNITS = EV (mV, UCUM, "mV")

6

>

CONTAINS

CODE

EV (F-38035, SRT, "ST Segment Finding")

1

U

DCID 3233 “ST Segment Morphology”

7

>

CONTAINS

CODE

EV (121071, DCM, "Finding")

1-n

U

DCID 3680 “ECG Lead Noise Descriptions”


TID 3715 ECG Measurement Source

The ECG Measurement Source Template provides a structure for identifying the particular cardiac cycle, or beat, in an analyzed ECG waveform used for the measurement group for which this template provides Observation Context. The cardiac cycle is identified by beat number, and optionally by specific temporal coordinates within a DICOM ECG Waveform SOP Instance.

Type:

Extensible

Order:

Significant

Table TID 3715. ECG Measurement Source

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

TEXT

EV (122149, DCM, "Beat Number")

1

U

Up to three numeric characters

2

CODE

EV (G-C036, SRT, "Measurement Method")

1

U

DCID 3676 “Lead Measurement Technique”

3

TCOORD

EV (121112, DCM, "Source of Measurement")

1

U

4

>

SELECTED FROM

WAVEFORM

1

U


Content Item Descriptions

Row 1

Beat Number is specified as a numeric text string, and shall be treated as the ordinal of the beat (cardiac cycle) within the waveform acquisition for this lead that was analyzed for the measurements in this container (i.e., "1" for the first beat, "2" for the second, etc.). If absent, the measurements may have been made by a technique across multiple cycles as specified in Row 2 Measurement Method.

Rows 3 and 4

Source of measurement identify the specific channel and time period within a DICOM ECG Waveform SOP Instance that was analyzed for the measurements in this container.

TID 3717 ECG Qualitative Analysis

The ECG Qualitative Analysis template allows a free text qualitative interpretation of the analyzed ECG, as well as a structure for a coded analysis.

Type:

Extensible

Order:

Significant

Table TID 3717. Qualitative Analysis, ECG

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

CONTAINER

EV (122145, DCM, "Qualitative Analysis")

1

M

2

>

CONTAINS

TEXT

EV (F-00033, SRT, "ECG Finding")

1

MC

At least one of rows 2 and 3 shall be present

3

>

CONTAINS

CODE

EV (F-00033, SRT, "ECG Finding")

1-n

MC

At least one of rows 2 and 3 shall be present

BCID 3230 “ECG Findings”

4

>>

HAS CONCEPT MOD

TEXT

EV (121051, DCM, "Equivalent Meaning of Value")

1

U

Interpretive statement

5

>>

INFERRED FROM

CODE

EV (F-00033, SRT, "ECG Finding")

1-n

U

No BCID; may use implementation-specific codes

6

>>>

HAS CONCEPT MOD

TEXT

EV (121051, DCM, "Equivalent Meaning of Value")

1

U

Interpretive statement


Content Item Descriptions

Row 3-4

ECG Finding provides one or more coded interpretive statements using standard or implementation-specific codes. Each coded finding will include a Code Meaning (0008,0104) using the LO Value Representation (64 characters); longer human-readable text strings may be conveyed in the Row 4 Equivalent Meaning of Value Content Item..

Row 5-6

Each primary ECG Finding of Row 3 may have multiple supporting coded findings in Row 5, with longer human-readable text strings if necessary in Row 6.

TID 3718 ECG Interpretive Statement (Retired)

This Template is retired. See PS3.16-2009.

TID 3719 Summary, ECG

Type:

Extensible

Order:

Significant

Table TID 3719. Summary, ECG

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

CONTAINER

EV (121111, DCM, "Summary")

1

M

2

>

CONTAINS

TEXT

EV (121111, DCM, "Summary")

1

U

3

>

CONTAINS

CODE

DT (18810-2, LN, "ECG overall finding")

1

U

DCID 3677 “Summary Codes ECG”