A.32.10.2 Real-Time Video Photographic Image IOD Entity-Relationship Model
This IOD uses the E-R Model in Section A.1.2, with only the Image IE below the Series IE.
Note
The Frame Pointers Module is included to managed the temporal synchronization with the video signal the IOD is referring, and optionally the spatial reference if each frame information contains a spatial position.
Table A.32.10-1. Real-Time Video Photographic Image IOD Modules
|
IE
|
Module
|
Reference
|
Usage
|
|
Patient
|
Patient
|
C.7.1.1
|
M
|
|
Clinical Trial Subject
|
C.7.1.3
|
U
|
|
Study
|
General Study
|
C.7.2.1
|
M
|
|
Patient Study
|
C.7.2.2
|
U
|
|
Clinical Trial Study
|
C.7.2.3
|
U
|
|
Series
|
General Series
|
C.7.3.1
|
M
|
|
Clinical Trial Series
|
C.7.3.2
|
U
|
|
Equipment
|
General Equipment
|
C.7.5.1
|
M
|
|
Enhanced General Equipment
|
C.7.5.2
|
M
|
|
Frame of Reference
|
Frame of Reference
|
C.7.4.1
|
C - Required if multiple instances are spatially related or if the Camera Position Functional Group Module is present in the Current Frame Functional Groups Module
|
|
Synchronization
|
C.7.4.2
|
M
|
|
Image
|
General Image
|
C.7.6.1
|
M
|
|
General Reference
|
C.12.4
|
U
|
|
Real-Time Bulk Data Flow
|
C.7.6.26
|
M
|
|
Acquisition Context
|
C.7.6.14
|
M
|
|
Device
|
C.7.6.12
|
U
|
|
Specimen
|
C.7.6.22
|
C - Required if the Imaging Subject is a Specimen
|
|
VL Image
|
C.8.12.1
|
M
|
|
ICC Profile
|
C.11.15
|
U
|
|
SOP Common
|
C.12.1
|
M
|
|
Common Instance Reference
|
C.12.2
|
M
|
|
Real-Time Acquisition
|
C.7.6.28
|
M
|
|
Current Frame Functional Groups
|
C.7.6.27
|
M
|