| DICOM PS3.20 2017a - Imaging Reports using HL7 Clinical Document Architecture |
|---|
An inFulfillmentOf element represents the Placer Order. There may be more than one inFulfillmentOf element in the case where a single report is fulfilling multiple orders. There SHALL be one inFulfillmentOf/order for each distinct Order associated with the report.
In each inFulfillmentOf/order there SHALL be one order/id for the Placer Order Number (0040,2016). There SHALL be one order/ps3-20:accessionNumber for the DICOM Accession Number (0008,0050) associated with the order. The ps3-20:accessionNumber SHALL be Data Type II; it SHALL have a UID root attribute identifying its assigning authority, and the DICOM Accession Number SHALL be in the extension attribute.
Example 8.2.3-1. inFulfillmentOf example
<xs:schema ...
xmlns:ps3-20="urn:dicom-org:ps3-20"
...
</xs:schema>
<inFulfillmentOf>
<order>
<id extension="089-927851" root="2.16.840.1.113883.19.4.33"/>
<!-- {extension} =
Placer Order Number/Imaging Service Request (0040,2016) {root} =
Order Placer Identifier Sequence (0040,0026) > Universal Entity ID (0040,0032) -->
<ps3-20:accessionNumber extension="10523475" root="2.16.840.1.113883.19.4.27" />
<!-- {extension}=
Accession Number (0008,0050) {root} =
Issuer of Accession Number Sequence (0008,0051) > Universal Entity ID (0040,0032) -->
<code code="RPID24"
displayName="CT HEAD WITH IV CONTRAST"
codeSystem="2.16.840.1.113883.6.256"
codeSystemName="RadLex Playbook">
<!-- Ordered Procedure Code is
Requested Procedure Code Sequence (0032,1064) -->
</order>
</inFulfillmentOf>