| DICOM PS3.16 2016d - Content Mapping Resource |
|---|
The details of a composite feature are expressed in this Template. It is applied to Mammography CAD Composite Feature (TID 4004 “Mammography CAD Composite Feature”).
Table TID 4005. Mammography CAD Composite Feature Body
|
DCID 6035 “Composite Feature Relations” The value shall be (111155, DCM, "Target content items are related contra-laterally") if the parent Content Item has code value (F-01792, SRT, "Focal asymmetric breast tissue") or (F-01793, SRT, "Asymmetric breast tissue"). |
||||||||
|
May be present only if value of parent is not (111102, DCM, "Non-lesion") |
||||||||
|
If the measured path is encoded, the SCOORD and its by-reference relationship to the IMAGE in TID 1400 “Linear Measurement” shall be used. |
||||||||
|
If the measured path is encoded, the SCOORD and its by-reference relationship to the IMAGE in TID 1401 “Area Measurement” shall be used. |
||||||||
|
If the measured path is encoded, the SCOORD and its by-reference relationship to the IMAGE in TID 1402 “Volume Measurement” shall be used. |
||||||||
|
DCID 6037 “Mammography Quantitative Temporal Difference Type” |
May be present only if the value of (111016, DCM, "Composite type") is (111153, DCM, "Target content items are related temporally") |
UNITS = DCID 7460 “Units of Linear Measurement” UNITS = DCID 7461 “Units of Area Measurement” |
||||||
|
The referenced numeric values shall have the same Concept Name. Their UNITS shall be the same as row 11 |
||||||||
|
May be present only if the value of (111016, DCM, "Composite type") is (111153, DCM, "Target content items are related temporally") |
DCID 6038 “Mammography Qualitative Temporal Difference Type” |
|||||||
|
The referenced code values shall have the same Concept Name and be from the same context group. |
||||||||
|
May be present only if value of parent is (F-01791, SRT, "Mammographic breast mass") or (F-01796, SRT, "Mammography breast density") |
||||||||
|
May be present only if value of parent is (F-01791, SRT, "Mammographic breast mass") or (F-01796, SRT, "Mammography breast density") |
||||||||
|
May be present only if value of parent is (F-01791, SRT, "Mammographic breast mass") or (F-01796, SRT, "Mammography breast density") |
||||||||
|
May be present only if value of parent is (F-01775, SRT, "Calcification Cluster") or (F-01776, SRT, "Individual Calcification") |
||||||||
|
May be present only if value of parent is (F-01775, SRT, "Calcification Cluster") |
||||||||
|
May be present only if value of parent is (F-01775, SRT, "Calcification Cluster") |
||||||||
|
The likelihood that the feature analyzed, and classified by the CODE specified in the Composite Feature parent Template, is in fact that type of feature. |
|
|
If dimensions for a volume are to be stated in terms of length, width, and depth, then one shall use 3 instances of TID 1400 “Linear Measurement”. |
|
|
Values ≤ 0 are allowed. The two referenced numeric values are Target Content Items of the first generation Composite Feature or Single Image Finding children of this composite feature. Given the equation, A - B, the value representing A shall be referenced first. |
|
|
The two referenced code values are Target Content Items of the first generation Composite Feature or Single Image Finding children of this composite feature. |