DICOMSRV configuration parameters related to DICOM communications are below. A blank cell under the 'Default Value' heading indicates that there is no default value for the specific configuration attribute.
Table C.4.2-14. Configuration Parameters Table
|
Parameter |
Configurable |
Default Value |
|---|---|---|
|
General Parameters |
||
|
Time-out waiting for acceptance or rejection Response to an Association Open Request |
Yes |
30 Seconds |
|
Time-out waiting for response to TCP/IP connect() request. |
Yes |
15 Seconds |
|
Time-out for waiting for data between TCP/IP packets. (Low-level timeout) |
Yes |
15 Seconds |
|
Time-out waiting for a response to a DIMSE Request |
Yes |
30 Seconds |
|
Time-out waiting for the next DIMSE Request |
Yes |
60 Seconds |
|
Debugging Capabilities |
||
|
Hex Dump DIMSE Messages |
Yes |
Off |
|
Hex Dump Association Messages |
Yes |
Off |
|
TCP/IP Settings |
||
|
TCP/IP Send Buffer |
Yes |
65535 Bytes |
|
TCP//IP Receive Buffer |
Yes |
65535 Bytes |
|
PacketFilter |
Yes |
On. This option enables running of tcpdump utility from the command line to capture TCP packet headers/contents |
|
DICOMSRV Parameters |
||
|
Maximum Number of Simultaneous Associations |
Yes |
20 |
|
Maximum Number of Associations to a given device |
Yes |
3 |
|
Maximum PDU size the AE can receive |
Yes |
65536 Bytes |
|
Maximum PDU size the AE can send |
No |
The lower of the value above and the max PDU size specified by the Remote AE in the Association Request |
|
Validation of DICOM Service Messages |
Yes |
Validate messages and log validation errors. Do not automatically return error for all validation errors |
|
Modality Worklist Parameters |
||
|
Maximum Number of Matches for an MWL Request |
Yes |
100 |
|
Time period after Scheduled Date/Time to leave SPS entries in the SPS Worklist |
Yes |
2880 min |
|
State of Parent Procedure that causes deletion of child SPS Entries |
Yes |
PROCEDURE STARTED |
|
Supported Transfer Syntaxes |
Yes |
Explicit VR Little Endian Implicit VR Little Endian |
|
Modality Performed Procedure Step Parameters |
||
|
Generate charges based on supplies specified in MPPS transactions |
Yes |
Off |
|
Purge Period for MPPS transactions in final state |
Yes |
30 days |
|
State to automatically set procedures to for a given AE on receipt of matching N-CREATE |
Yes |
|
|
State to automatically set procedures to for a given AE on receipt of matching N-SET COMPLETED |
Yes |
|
|
State to automatically set procedures to for a given AE on receipt of matching N-SET DISCONTINUED |
Yes |
|
|
Flag specifying support for IHE Trauma cases for a given AE |
Yes |
false |
|
Patient ID Range to be used for Patient Registration for IHE Trauma case |
Yes |
|
|
Default Procedure Code to be used for orders for IHE Trauma cases |
Yes |
|
|
Supported Transfer Syntaxes |
Yes |
Explicit VR Little Endian Implicit VR Little Endian |