A.7.2.6 ReferencedFrames

This act class shall be used if the referenced DICOM SOP instance is a multi-frame image and the reference does not apply to all frames. The list of integer values for the referenced frames of a DICOM multi-frame image SOP instance is contained in the Boundary ActClass.

Table A.7.2-4. DICOM Referenced Frames in an HL7 V3 Act

Attribute

Data Type

Multiplicity

Value

classCode

CS

1..1

ROIBND

moodCode

CS

1..1

EVN

templateId

LIST<II>

1..*

code

CV

1..1

< Code Value (0008,0100): 121190 as code property, 1.2.840.10008.2.16.4 as codeSystem property, DCM as codeSystemName property, Code Meaning (0008,0104): "Referenced Frames" as displayName property>


A.7.2.6.1 CDA Mapping (Class Name and Attributes used for CDA Documents)
  • Act Clone Name: Observation

  • Act clone name of the CDA entry is "Observation" instead of "ReferencedFrames"

  • templateId value (Table A.7.1-4): Set root portion of II to "2.16.840.1.113883.10.20.6.2.10" (identifies the template that defines constraints on "Referenced Frames Observation" of CDA Diagnostic Imaging Reports as specified by CDA R2 DIR IG).