The following is a simple and non-comprehensive illustration of an encoding of the Chest CAD SR IOD for chest computer aided detection results. For brevity, some mandatory content items are not included, such as several acquisition context content items for the images in the Image Library.
A chest CAD device processes a typical screening chest case, i.e., there is one image and no nodule findings. Chest CAD runs lung nodule detection successfully and finds nothing.
The chest radiograph resembles:
The content tree structure would resemble:
|
Node |
Code Meaning of Concept Name |
Code Meaning or Example Value |
TID |
|---|---|---|---|
|
1 |
Chest CAD Report |
||
|
1.1 |
Image Library |
||
|
1.1.1 |
IMAGE 1 |
||
|
1.1.1.1 |
Image View |
Postero-anterior |
|
|
1.1.1.2 |
Study Date |
19980101 |
|
|
1.2 |
CAD Processing and Findings Summary |
All algorithms succeeded; without findings |
|
|
1.3 |
Summary of Detections |
Succeeded |
|
|
1.3.1 |
Successful Detections |
||
|
1.3.1.1 |
Detection Performed |
Nodule |
|
|
1.3.1.1.1 |
Algorithm Name |
"Lung Nodule Detector" |
|
|
1.3.1.1.2 |
Algorithm Version |
"V1.3" |
|
|
1.3.1.1.3 |
Reference to node 1.1.1 |
||
|
1.4 |
Summary of Analyses |
Not Attempted |