This act class shall be used if the referenced DICOM SOP instance is a multi-frame image and the reference does not apply to all frames. The list of integer values for the referenced frames of a DICOM multi-frame image SOP instance is contained in the Boundary ActClass.
Table A.7.2-4. DICOM Referenced Frames in an HL7 V3 Act
|
Attribute |
Data Type |
Multiplicity |
Value |
|---|---|---|---|
|
classCode |
CS |
1..1 |
ROIBND |
|
moodCode |
CS |
1..1 |
EVN |
|
templateId |
LIST<II> |
1..* |
|
|
code |
CV |
1..1 |
< Code Value (0008,0100): 121190 as code property, 1.2.840.10008.2.16.4 as codeSystem property, DCM as codeSystemName property, Code Meaning (0008,0104): "Referenced Frames" as displayName property> |
Act Clone Name: Observation
Act clone name of the CDA entry is "Observation" instead of "ReferencedFrames"
templateId value (Table A.7.1-4): Set root portion of II to "2.16.840.1.113883.10.20.6.2.10" (identifies the template that defines constraints on "Referenced Frames Observation" of CDA Diagnostic Imaging Reports as specified by CDA R2 DIR IG).